Mastering Cannula Selection: A Guide to Sizes, Color Codes, and Best Practices

cannula color coding

Introduction 

Grasping cannula size and color plays a key role for medical professionals to carry out safe and effective procedures. A cannula is a slim tube that doctors use for many medical tasks. It comes in various sizes and has color codes to help identify it.

The color-coding system for cannulas lets healthcare professionals pick the right cannula for their needs. According to the Infusion Nurses Society (INS), the standard cannula colors codes include:

COLOR CODE GAUGEOD m.m.LENGTH
Orange14 Gauge2.1045
Grey16 Gauge1.7045
White17 Gauge1.5045
Green 18 Gauge 1.3045
Pink20 Gauge1.0033
Blue22 Gauge0.8525
Yellow 24 Gauge 0.7019
Purple 26 Gauge0.6019

Different sizes of cannulas are used for patients with specific needs.

16-18G: For rapid transfusions of fluid in adults.

20-22G: For routine transfusions, such as medication, in adults.

22G-24G: Recommended for pediatric use. 

24G-26G: For Infants and Neonates.

An IV cannula has many important parts for fluid administration. It consists of 8 parts.

  1. Needle
  2. Catheter
  3. Wings
  4. Injection port caps
  5. valve
  6. Needle holder
  7. Flashback chamber
  8. Cap or port

Cannulization

Cannulization is the processof inserting an IV catheter into a vein. It serves various essential purposes, including administering IV fluids, collecting blood samples, and delivering medications. But before introducing cannula in the vein, it’s crucial to follow strict aseptic precautions to ensure safety and success. 

Essential tools required:

  • Disposable gloves
  • Hand sanitizer
  • Cotton
  • Alcohol spirit swab
  • Tourniquet
  • Cannula of suitable size
  • Adhesive tape

Now starts the procedure:

  • Take the patient’s consent.
  • Wear disposable gloves. 
  • Have the patient sit comfortably and identify a straight vein in the hand or forearm suitable for the cannula size. 
  • Tie a tourniquet 5-10 cm above the chosen vein. Clean the area with an alcohol swab for aseptic preparation. 
  • Open the cannula and check for any defects. Hold the handle correctly and insert the cannula at a 15 to 30-degree angle. 
  • Once a third of the catheter is in, check to confirm cather’s entry into the vein. 
  • Slightly retract the needle and fully advance the catheter into the vein. Release the tourniquet and remove the needle, capping the catheter to prevent blood flow. 
  • Secure the cannula with adhesive tape and ensure it functions by flushing with saline. Ejection of waste and needles correctly. 

Common Mistakes to Avoid with Cannula Color Coding 

When talking about medical profession, precison and accuracy are the key factors. IV cannula (of specific size and color) plays a crucial role in this field to ensure that. 

To enusre that efficient and safe care of the patient, medical professioanl must avoid the following mistakes while using cannula. 

  1. Misinterpretation Of Colors

Misinterpretaion of the color codes of cannula is one frequent mistake witnessed. Each of the color codes (given in the above table) represents a specific gauge. When misread, it can lead to using an inappropriate cannula for the procedure. 

For example: If one uses small gauge (large needle) in the place of larger gauge (smaller needle), it can block the fluid flow and the opposite can even cause vein damage. 

  1. Inadequate training and education 

Inadequate training of healthcare professionals on cannula color coding can lead to mistakes. Without proper education, staff may not understand the coding system, which can lead to mistakes. 

Healthcare institutions must ensure regular training and assessments to ensure that all staff are well-informed and skilled in this area. 

  1. Poor Lightening Condition 

In the poor lightening of the emergency wards, differentiating the colors codes can be challenging and lead to error. For example, pink (20G) and orange (14G) may appear similar in dim lighting conditions. 

Making sure wards are well-lit and using enough lighting tools can reduce this problem.

  1. Label Wear and Tear

Cannula color coding labels and packaging can fade over time, making colors codes hard to see. Regularly check and replace worn labels and packaging to avoid mistakes. Store them properly to make the color labels last longer.

Medical operations require team work. Many times an poor instructions or unclear communication can also cause the staff to make mistakes. Thus, visual inspection of right color and size of the cannula can also help in avoiding any probable error. 

Conclusion 

Following standerdized color codes of cannula published by a reliable source helps in accurate selection, erasing risk chances, and bettering patient care. 

The above guide can help the medical professioanls to understand the nuances of IV cannula sizes, colors, flow rates, and usage. It will help them make informed decisions to optimize patient care. 
As a trusted IV cannula provider, Romsons inclines towards improving healthcare sector, focusing on patient well-being and effective medical solutions.

Picture of romsons

romsons

Leave a Replay